Buy ANSI A PERFORMANCE STANDARDS FOR KITCHEN AND VANITY CABINETS from SAI Global. Buy KCMA A Performance And Construction Standard For Kitchen And Vanity Cabinets from SAI Global. Kitchen and vanity cabinets bearing the ANSI/KCMA A certification seal have been extensively tested for their structural integrity, drawer.

Author: Kazigul Tojaramar
Country: Bermuda
Language: English (Spanish)
Genre: History
Published (Last): 13 November 2004
Pages: 327
PDF File Size: 1.88 Mb
ePub File Size: 4.84 Mb
ISBN: 504-9-68289-841-1
Downloads: 10710
Price: Free* [*Free Regsitration Required]
Uploader: Tautilar

The cycle is repeated five times. Cabinet doors are weighted with 65 pounds and operated 10 times to test the ability of door and hinges to withstand loading. To test the ability of drawers and drawer mechanisms to operate with loading during normal use, drawers are loaded at 15 pounds per square foot and operated through 25, cycles.

This ensures the cabinets will live up to your expectations. The maximum number of products that can be compared is 4. For information on the certification or to locate a certified cabinet manufacturer, visit the Certifications portal at KCMA. Skip to main content. The finish must then show no appreciable discoloration and no evidence of blistering, cold checking, or other film failure.

The strength behind certified cabinetry: ANSI/KCMA A161.1

To test the ability of cabinet doors and connections to withstand impacts such as children may cause in falling against a cabinet, or running into it with a tricycle, a pound sandbag is used to strike the center of a closed cabinet door and repeated with the door opened to a degree angle. Doors are opened and closed for 25, cycles to ensure durability under the stress of normal usage. Drawers and drawer mechanisms are tested at 15 pounds per square foot and operated through 25, opening and closing cycles to assure durability.

Installed wall cabinets are loaded with pounds to ensure that the cabinet will accept net loading in compliance with ANSI A To test the ability of doors, door-holding devices, hinges and attachment devices to operate under the stress of normal use, doors are opened and closed through a full degree swing for 25, cycles. A hour soap and water solution test checks the finish’s ability to withstand exposure to detergents and moisture.

The door must remain weighted for 10 minutes, after which the door and hinges must show no visible signs of damage, and connections between cabinet-and-hinge and door-and-hinge must show no sign of looseness. After the test the drawer must not be damaged and must operate as before the test, with no visible sign of joint separation or failure of any part of the cabinet or mounting system.

  ISENGARD AND NORTHERN GONDOR PDF

These verify the structural integrity and strength of the cabinets. These include participation and review by consumer anzi supplier organizations, builders, remodelers, the U.

Finish is exposed to vinegar, grape juice, olive oil, lemon juice, proof alcohol and more to ensure no appreciable discoloration, stain or whitening of the finish anso. A 3 pound steel ball is “drop tested” against shelves, cabinet bottoms and drawer bodies to ensure cabinets will withstand dropping of cans and other items. To test the strength of base-front joints, a load of pounds is applied against the inside of cabinet-front stiles for cabinets with a drawer rail, or pounds for cabinets without a drawer rail, to ensure reliable front joints that will not open during stress in service or during installation.

Please refine your selection. A 3 pound weight is dropped 10 times against the drawer assembly to ensure that the drawer front assembly will withstand the impact of closing.

Mastercraft Cabinets | KCMA Certification Program, ANSI Standards

Your recommendation is being sent! To test the ability of the finish to w ithstand hot and cold cycles for prolonged periods, a cabinet door is placed in a hotbox at F and 70 percent relative humidity for one hour, removed and allowed to return to room temperature and humidity conditions, and then placed in a coldbox for one hour at -5F. On all cabinets, the shelves and bottoms are loaded at 15 pounds per square foot, with the weight maintained for seven days to ensure that there is no excessive deflection and no visible sign of joint separation or failure of any part of the cabinets or the mounting system.

Shelves and bottoms are loaded at 15 pounds per square foot to ensure no excessive deflection or joint failure on the cabinet or mounting system.

Cabinets are impact tested by striking the center of a closed and open door with a 10 pound sand bag. After 10 drops, there must be no evidence of looseness or structural damage to the drawer-front assembly that impairs its operation. The drawers must then remain operable with no failure in any part of the drawer assembly or operating system, and drawer bottoms ajsi not be deflected to interfere with drawer operation. Your Email has been successfully sent!

  CISCO SG100-24 PDF

The weighted a11.1 is slowly operated for 10 cycles from 90 degrees open to 20 degrees open, and returned to the degree position. To test the ability of doors, hinges, and means of attachment to withstand loading, 65 pounds of weight is applied on the door.

The door edge must then show no delamination or swelling and no appreciable discoloration or evidence of blistering, checking, whitening, or other film failure.

Welcome to our redesigned homepage! In order to be certified, cabinets must also undergo eight categories of testing, covering structural integrity, drawer and door anso and finish quality see sidebar below.

KCMA has sponsored the nationally recognized cabinet testing and certification program for more a161.11 45 years. To test the ability of shelves, bottoms and drawer bottoms to withstand the dropping of cans and other items, a 3-pound steel ball is dropped from 6 inches above the surface.

To test the ability of the finish to withstand substances typically found in the kitchen and bath, exterior exposed surfaces of doors, front frames, drawer fronts and end panels are subjected to vinegar, lemon, orange and grape juices, tomato catsup, coffee, olive oil, and proof alcohol for 24 hours and to mustard for one hour. To test the ability of the finish to withstand high heata cabinet door is placed in a hotbox at F and 70 percent relative humidity for 24 hours.

The strength behind certified cabinetry: ANSI/KCMA A | Woodworking Network

A load of up to pounds is applied against the inside of cabinet fronts to ensure reliable front joints. Scroll Down for more stories. The exceptions are sink fronts and bases, oven cabinets and refrigerator cabinets. The cabinet door must operate as before the test and show no damage or sign of separation or failure in the system.